Dkg307 user manual
The periodic maintenance is basically carried out after a given engine hours for example hours , but even if this amount of engine hours is not fulfilled, it is performed after a given time limit for example 12 months. The software allows the visualization and recording of all measured parameters. The recorded parameters may then be analyzed graphically and printed. Thanks to the weekly program feature unwanted operation of the genset may be prohibited.
These programmable parameters allow the genset to operate automatically only in allowed time limits. The events are recorded with a date and time stamp. The date and time information comes from the internal battery backed-up real time clock circuit of the unit.
To enter the program mode, press the MENU button for 5 seconds. Alarm will stop. If the period is set to 0, this will mean that the period is unlimited. Engine Heating Type This parameter defines the engine heating method.
Times are defined with 10 minute steps and are shown in the 3 digit display as the hours and the first digit of the minutes. If no operation is needed for a certain day of week, then the related time will be defined as The programmable properties of digital inputs are: -action to be taken upon arrival of the fault signal alarm, warning,etc The sender characteristics will be defined using maximum 6 points.
The values should be entered in the increasing order of ohm values. For unused points, ohm values should be entered as 0. An example table is given below. Definition Unit Std Val Description Exercise start day and This parameter defines the start day and hour hour of the exerciser.
Values higher or equal to mean that the exerciser is off. Max load 0. Digital inputs: input voltage 0 - 30 V-DC. Internally connected to battery positive via ohm resistor. Print page 1 Print document 29 pages. Rename the bookmark. Delete bookmark? Cancel Delete. Delete from my manuals? Sign In OR. Don't have an account? Sign up!
Restore password. Upload manual. Upload from disk. Upload from URL. Table of Contents. DKG User Manual. All programs may be modified via front panel. Last faults are stored in the event log file. Previous Page. Next Page. Introduction to the Control Panel 1.
Mounting the Unit 1. Wiring the Unit 2. Led Displays 3. Digital Displays 4. It shows the measured values on its displays. The unit is designed to provide user friendliness for both the installer and the user. The user should not be able to access parts of the unit other than the front panel. Mount the unit on a flat, vertical surface. Before mounting, remove the mounting brackets and connectors from the unit, then pass the unit through the mounting opening.
This terminal will supply the excitation current and measure the voltage of the charge alternator. They show: -Measured parameters, -Service counters, -Statistical counters, -Program parameters. Warning and alarm limits are separately programmable for the oil pressure sender input. Changing the operation mode while the genset is running will result into a behavior suitable for the new operating mode.
The unit offers 2 different ways of engine heating. The fuel pump is used in order to transfer fuel from the large capacity main tank if exists to the genset daily tank which is generally integrated in the chassis and has a limited capacity. The genset is requested to run only when battery voltage drops below the critical level. The dual genset intermittent operation uses also the Mains Simulation feature.
Please review chapter 6. The periodic maintenance is basically carried out after a given engine hours for example hours , but even if this amount of engine hours is not fulfilled, it is performed after a given time limit for example 12 months.
The new message will indicate all existing alarms, even masked ones. This is the same cable as PSTN land modems. The cable length should not be over 3 meters. The exercise operation may be done on a daily, weekly or monthly basis. The start day and time of the exercise is programmable as well as its duration.
The exercise may be done with or without load following programming. Gas Engine Fuel Solenoid Control The unit provides a special function for the fuel solenoid control of a gas engine.
The fuel solenoid of a gas engine is different from a diesel engine. It should be opened after the cranking has been started and should be closed between crank cycles. Firmware Update The unit offers possibility of updating the firmware in the field. The unit will go to firmware download mode with a special command from the PC program. Dual Voltage and Frequency The unit offers 2 sets of voltage and frequency protection limit values.
The user is allowed to switch between these 2 sets anytime.